GEL 104 programmable preselect counter

The counter works as coincidence counter. i.e. the output signals ( Out 1, Out 2) are activated when the preselected value is reached. Depending on system parameter programming, a monostable and also a bistable signal is available (20 ms, 50 ms, 100 ms, 500 ms, 1s). Resetting to zero or to the set value is achieved manually via the keyboard, electrically via the reset input or by programmed auto-reset.

Important: In the event of a bistable Out 2-signal, resetting can be achieved only via the keyboard.

  • many different control and counting functions programmable

  • multiplier for actual-value adaptation programmable

  • safe against mains failures

  • input frequency up to 40 kHz

  • two preselects and one set value

Technical data

GEL 104

  3c_104_g200x200_72dpi.gif

CD voltage

U B= 12 ... 24 V DC -5%/+10 %

AC voltage

115/230 V AC~/50 ... 60 Hz - 10%/+6%

Width x Height x Depth

96 mm x 48 mm x 108 mm

Display

7-segment-LED

Digits 6 of -99.999 to 999.999
Display height 14 mm
max. count frequency 40 kz
 
 